Minggu, 08 Mei 2016

pka 2.3.2.2 Configuring Rapid PVST+

Konfigurasi pada Switch
S1
S1>ena
S1#conf t
Enter configuration commands, one per line. End with CNTL/Z.
S1(config)#vlan 10
S1(config-vlan)#vlan 20
S1(config-vlan)#vlan 30
S1(config-vlan)#vlan 40
S1(config-vlan)#vlan 50
S1(config-vlan)#vlan 60
S1(config-vlan)#vlan 70
S1(config-vlan)#vlan 80
S1(config-vlan)#vlan 99
S1(config-vlan)#exit
S1(config-vlan)#int vlan 99
S1(config-if)#ip address 172.17.99.11 255.255.255.0
S1(config)#int range fa0/1-4
S1(config-if-range)#sw
S1(config-if-range)#switchport mode trunk
S1(config-if-range)#switchport trunk native vlan 99
S1(config-if-range)#end
S1#ping 172.17.99.12
S1#ping 172.17.99.13
S1#conf t
S1(config)#spanning-tree mode rapid-pvst
S1(config)#spanning-tree vlan 1 root primary
S1(config)#spanning-tree vlan 10 root primary
S1(config)#spanning-tree vlan 30 root primary
S1(config)#spanning-tree vlan 50 root primary
S1(config)#spanning-tree vlan 70 root primary
S2
S2>ena
S2#conf t
Enter configuration commands, one per line. End with CNTL/Z.
S2(config)#int range fa0/11, fa0/18, fa0/6
S2(config-if-range)#switchport mode access
S2(config-if-range)#no shutdown
S2(config-if-range)#exit
S2(config)#vlan 10
S2(config-vlan)#vlan 20
S2(config-vlan)#vlan 30
S2(config-vlan)#vlan 40
S2(config-vlan)#vlan 50
S2(config-vlan)#vlan 60
S2(config-vlan)#vlan 70
S2(config-vlan)#vlan 80
S2(config-vlan)#vlan 99
S2(config-vlan)#exit
S2(config)#int fa0/6
S2(config-if)#switchport access vlan 30
S2(config-if)#int fa0/18
S2(config-if)#switchport access vlan 20
S2(config-if)#int fa0/11
S2(config-if)#switchport access vlan 10
S2(config-if)#exit
S2(config)#int vlan 99
S2(config-if)#ip address 172.17.99.12 255.255.255.0
S2(config-if)#end
S2#show vlan brief
S2#conf t
S2(config)#int range fa0/1-4
S2(config-if-range)#switchport mode trunk
S2(config-if-range)#switchport trunk native vlan 99
S2(config-if-range)#exit
S2(config)#spanning-tree mode rapid-pvst
S2(config)#spanning-tree vlan 1 root secondary
S2(config)#spanning-tree vlan 10 root secondary
S2(config)#spanning-tree vlan 20 root secondary
S2(config)#spanning-tree vlan 30 root secondary
S2(config)#spanning-tree vlan 40 root secondary
S2(config)#spanning-tree vlan 50 root secondary
S2(config)#spanning-tree vlan 60 root secondary
S2(config)#spanning-tree vlan 70 root secondary
S2(config)#spanning-tree vlan 80 root secondary
S2(config)#spanning-tree vlan 99 root secondary
S2(config)#int range fa0/11, fa0/18, fa0/6
S2(config-if-range)#spanning-tree portfast
S2(config-if-range)#int range fa0/11, fa0/18, fa0/6
S2(config-if-range)#spanning-tree bpduguard enable

S3
S3>ena
S3#conf t
Enter configuration commands, one per line. End with CNTL/Z.
S3(config)#vlan 10
S3(config-vlan)#vlan 20
S3(config-vlan)#vlan 30
S3(config-vlan)#vlan 40
S3(config-vlan)#vlan 50
S3(config-vlan)#vlan 60
S3(config-vlan)#vlan 70
S3(config-vlan)#vlan 80
S3(config-vlan)#vlan 99
S3(config-vlan)#exit
S3(config)#int vlan 99
S3(config-if)#ip address 172.17.99.13 255.255.255.0
S3(config-if)#exit
S3(config)#int range fa0/1-4
S3(config-if-range)#switchport mode trunk
S3(config-if-range)#switchport trunk native vlan 99
S3(config-if-range)#exit
S3(config)#spanning-tree mode rapid-pvst
S3(config)#spanning-tree vlan 20 root primary
S3(config)#spanning-tree vlan 40 root primary
S3(config)#spanning-tree vlan 60 root primary
S3(config)#spanning-tree vlan 80 root primary
S3(config)#spanning-tree vlan 99 root primary



Tidak ada komentar:

Posting Komentar